Our Health Library information does not replace the advice of a doctor. Please be advised that this information is made available to assist our patients to learn more about their health. Our providers may not see and/or treat all topics found herein. Vision is the result of electrical signals that travel between the retina and the part of the brain involved with vision (occipital cortex). Electrophysiology tests check to see how well this visual nerve pathway sends the electrical signals needed for vision. These tests measure electrical activity that occurs in your eye when you look at something. Electrophysiology includes different tests that measure how well the retina works. It can help check for diseases of the retina. The tests may also help diagnose and evaluate different kinds of vision and health problems. ERG measures the retina's electrical response while you look at different patterns or flashes of light. An ERG test can check for diseases and problems of the retina. A full-field ERG can check how well your entire retina is working. A multifocal ERG (mfERG) tests just part of the retina. It can check for diseases of the macula and for central vision loss. EOG tests how well electrical currents are working in the whole eye. It is done to check for certain eye and retina problems. VER tests the electrical activity in the whole visual pathway, from the eyes to the parts of the brain involved with vision. Like ERG, this test measures electrical activity when the eye responds to looking at something. A VER test can find problems by showing how brain waves respond to certain things you look at during the test. The different electrophysiology tests are done for different reasons. A full-field ERG measures how well rod and cone cells are working. These cells help you detect light and color. This test also looks at other cells in the retina. It may be used to check for problems such as: A full-field ERG may help find the cause of certain retina problems, such as vitamin A deficiency or metabolic disorders. A multifocal ERG (mfERG) tests the electrical response in the central part of the retina. It may be used to help check for: An electro-oculogram is used to help diagnose problems of the retina. It may be used to help check for problems such as: Visual evoked response (VER) measures how well the whole visual pathway between the eye and the brain is working. The test may be used to check for or evaluate conditions such as retina problems, optic nerve problems, and multiple sclerosis. VER can be used to check vision problems in people who can't take other eye tests. This includes infants or patients who can't respond to or follow instructions. You don't need to do anything special to prepare for the tests. Follow any instructions your doctor gives you about what to do before your test. For visual evoked response (VER): The way each electrophysiology test is done varies. During the test: A computer records changes in your brain waves while you look at patterns. Electrical signals are measured in the visual pathway, the area of the brain involved with vision (primary visual cortex). During the test: These tests most often cause little or no discomfort. Tests include electroretinography (ERG), electro-oculography (EOG), and visual evoked response (VER). The electrode used for an ERG test may feel like having an eyelash stuck on your eye. There are usually no risks from these tests. Tests include electroretinography (ERG), electro-oculography (EOG), and visual evoked response (VER). After an ERG test, avoid rubbing your eyes for at least an hour. Rubbing your eyes may scratch the front of your eye (cornea). The test measures the amplitude (height) of certain brain waves (A-waves and B-waves) to detect vision problems. The time it takes for the eye to respond to light stimulus is called latency. Possible results are: Test results use a number measurement called the Arden ratio. This is the ratio of the eye's maximum electrical activity in light to the minimum electrical activity in the dark. Current as of: July 31, 2024 Author: Ignite Healthwise, LLC Staff Current as of: July 31, 2024 Author: Ignite Healthwise, LLC Staff Clinical Review Board This information does not replace the advice of a doctor. Ignite Healthwise, LLC disclaims any warranty or liability for your use of this information. Your use of this information means that you agree to the Terms of Use and Privacy Policy. Learn how we develop our content. To learn more about Ignite Healthwise, LLC, visit webmdignite.com. © 2024 Ignite Healthwise, LLC.Topic Contents
Electrophysiology Tests for the Eyes
Test Overview
Electroretinography (ERG)
Electro-oculography (EOG)
Visual evoked response (VER)
Why It Is Done
Electroretinography (ERG)
Electro-oculography (EOG)
Visual evoked response (VER)
How To Prepare
How It Is Done
Electroretinography (ERG)
Electro-oculography (EOG)
Visual evoked response (VER)
How It Feels
Risks
Results
Electroretinography (ERG)
Electro-oculography (EOG)
Visual evoked response (VER)